SUPERINTENDING ENGINEER
Construction of new 33/11 KV Substation alongwith its associate 33KV and 11KV line
- Supply, Installation, Testing & Commisioning Of 2 X 5Mva, 33 / 11Kv S / S 2 Nos.Including Civil Work, At Dhadari & Hatwaha a) 33 KV line : 11.82 KM b) 11 KV line : 3.90 KM
- Supply, Installation, Testing & Commisioning Of 3 X 3.15Mva, 33 / 11Kv S / S 3Nos, Including Civil Work, At Lugasi, Vikrampur & Darguwah c) 33 KV Line : 51.90 KM d) 11 KV Line 7.20 KM
DY. Chief Electrical Engineer
Modification/shifting of over head 33kv Powerline crossing by providing under ground HT XLPE cable between Tikamgarh-Chhatarpur Section of new B.G.Line
- 33KV 300 Sqmmx3 Core HT XIpe cable laying : 830 mtr
- 2.11KV 185 Sqmmx3 Core HT Xlpe cable laying : 1818 mt Total 2648 mtr 1. Jointing Kit 33KV : 15 Nos. 2. Jointing Kit 11KV : 32 Nos.
DY. Chief Electrical Engineer
Power Supply arrangement by separate 11kV feeder from MPSEB substation to Chhanera Railway station alongwith one VCB of Bhopal Division of WC Railway.
Extensionof 11 KV line on H-beam 152×152 mm 37-1 kg/Mtr. 11 mtrs long with AAAC Rabbit conductor as per Railway technical data . Supply & fixing of 11KV feeder control VCB, 200A with CT’s.
Dy. Chief Electrical Engineer
Modification/shifting of over head 33kv Power Line crossing by providing underground HT XLPE cable between Tikamgarh-Chhatarpur Section of new B.G.Line.
- 1.11KV 185 SammX3 Core HT Xlpe cable laying : 5374 mtr.
- 2.33KV 300 Sommx3 Core HT Yipe Cable Laying : 1764 m
Total 7438 mtr 1. Jointing Kit 11KV : 44 Nos 2. Jointing Kit 33KV : 18 Nos.
SUPERINTENDING ENGINEER
Replacement of Overhead Power Line (ACSR Conductor) at Harda, Bina & Guna Station of Bhopal division of WC Railway.
Replacement of Overhead Power Line (ACSR Conductor) at Harda, Bina & Guna Station of Bhopal division of WC Railway.
Dy. Chief Electrical Engineer
Supply , errection, commission of provision of Auxiliary Transformer in Connection with Interlocking of L.C Gates for Automatic Block Signalling and Power Lifting Barriers at Different L.C Gates Over Bhopal Division.
SUPERINTENDING ENGINEER
Modification to OHE in connection with Construction of additional platforms no.6&7 at Itarsi station of Bhopal division
Modification to OHE in connection with Construction of additional platforms no.6&7 at Itarsi station of Bhopal division
ADDL. General Manager
Turnkey basis the work of construction of shifting 33KV, 11KV, LT Line & 11 / 0.4KV Distribution Transformers Causing Obstruction in the proposed BRTS Corridor Route for Bhopal City Area from Habibganj underbridge to MPNagar Board Office Square
- 33KV line : 4.5 KM
- 11KV line : 4.0 KM
- LT line : 0.5 KM
- Sub Station 11 / 04KV : 7 Nos.
Chief Electrical Engineer
Electrification of staff quarters of Type – 1-72 units at JBP and Type – 1-50 units & Type – III – 6 units at JBP – Sub – Dn Railway stations along with Power supply arrangement at Jabalpur, WCR, JBP – Division.
Electrification of staff quarters of Type – 1-72 units at JBP and Type – 1-50 units & Type – III – 6 units at JBP – Sub – Dn Railway stations along with Power supply arrangement
Dr. Chief Electrical Engineer
Provision of 2 x 1000 kVA, 33/11kV substation at Burn complex , Jabalpur
Supply , errection , testing & commissioning of battery and 30V, 2.2V per cell , 100AH capacity lead acid battery with wooden stand duly painted with epoxy paint.
ADDL. General Manager
Turnkey basis of complete including laying of 33 KV line (Double Circuit) from newly proposed 100 KVA transformer at 220 KV S / S Chambal and Amrawad Khurd EHV 220 KV S / S for interconnection with existing 33 KV S / S Amrawad, Sidharth Lake City & Ballabh Nagar 33/11 KV S / S Route Length 8.85 Km.
complete including laying of 33 KV line (Double Circuit) from newly proposed 100 KVA transformer at 220 KV S / S Chambal and Amrawad Khurd EHV 220 KV S / S for interconnection with existing 33 KV S / S Amrawad, Sidharth Lake City & Ballabh Nagar 33/11 KV S / S Route Length 8.85 Km.
Dy. Chief Electrical Engineer
Electrification of Station Building, Platform , Circulating Area And Power Supply Arrangements At Ratwas and Hinotiya-Pipalkheda Station In Bina-Guna Section Of Bhopal Division.
Power Supply Arrangement at Ratwas and Hinotia-Pipalkhera Station
Chief Electrical Engineer
Provision of Boring earth for 33/11kV Sub station at Burn Complex. Boring earth for 33/11kV Sub station at Burn Complex.
Dy. Chief Electrical Engineer
Electrification of Station Building, Platform , FOB and power supply arrangement at Malkhedi station of JBP Division.
Power supply arrangement at Malkhedi station of JBP Divn.
Chief Electrical Engineer
Improvement to existing HT/LT power supply system at Bhopal & Habibganj on Bhopal Division of West Central Railway.
Improvement to existing HT/LT power supply system at Bhopal & Habibganj on Bhopal Division of West Central Railway
Dy. Chief Electrical Engineer
Rewiring of 855 nos. Different types old Railway Staff quarters ( Type-I , II , III, & IV and their equivalent), Cable laying work Over Head line work and provision of 1 no., 500 kVA, 33/0.415 kV Transformer at different stations over Bhopal Division.
DEVELOPMENT CORPORATION LTD
Design , Supply , Erection , Installation , Testing & Commissioning of electrical Work at Network Monitoring Centre Building at Arera Hills,Bhopal.
- 33kV Sub Station & 33kV line with 2 Nos.1600 KVA Dry Type Indoor Transformer
- 33kV HT Panel / SF – 6 (2 incomer, 2 outgoing and 1 bus coupler)
- DGSet 315kVA
- Servo Stablizer 1600KVA
- LT Control Main Panel, Control Panel & Bus Duct
- Two Six Passenger Lift & One Goods Lifts
Two Six Passenger Lift & One Goods Lifts
Bharat Engineering Company Limited.
Supply & Erection, Testing And Commissioning of Electrical items of 6.6KV Overhead Transmission line for BOP Satpura TPS , MPPGCL Project ( BP02)
Supply & Erection, Testing And Commissioning of Electrical items of 6.6KV Overhead Transmission line for BOP Satpura TPS , MPPGCL Project ( BP02)
KHETRA VIDYUT VITARAN CO.LTD.
33 KV independent feeder by laying an extension of 4.7 Kms . 33KV Double Circuit Line on 15 Mtrs.long . ” H ” Beam on behalf of M / s John Deere (I ) Ltd. The independent 33KV feeder is emanating from 220KV S / s Bhopal Road , Dewas for New HT Connection of 3900KVA on 33KV Double Circuit Line with digital summation of multiple feeders so as to achieve summated energy Apex metering system for HT Consumer along with laying of 3 core 400 sq.mm. XLPE underground Cable up to a route length of 300 mtrs . of each length . The 33KV Line emanating from M.P.P.T.C.L. 220KV Sub Station Dewas with independent 2 Nos . 33 KV Bay to the premises of John Deere ‘ s Tractor manufacturing plant at Village Khatamba , Dewas ( M.P ) against M.P.P.K.V.V.C.L.Dewas
The independent 33KV feeder is emanating from 220KV S / s Bhopal Road , Dewas for New HT Connection of 3900KVA on 33KV Double Circuit Line with digital summation of multiple feeders so as to achieve summated energy Apex metering system for HT Consumer along with laying of 3 core 400 sq.mm. XLPE underground Cable up to a route length of 300 mtrs . of each length . The 33KV Line emanating from M.P.P.T.C.L. 220KV Sub Station Dewas with independent 2 Nos . 33 KV Bay
EXECUTIVE ENGINEER (ELECTRICAL)
External Electrification work at 23.35 Acres Land at Rau Indore
- Street Light Pole (Steel Tubular Polo) : 200 Nos.
- Underground 11kV 3 core 300 sqmm & 240 sqmm Armored (XLPE) Cable : 1.483 KM. & 1.757 KM. resp.
- Underground LT 3.5 core 300&150 sqmm Armored (XLPE) Cable : 4.802&4.571 KM.resp.
- Underground LT 4 core 16& 10 sqmm Armored (XLPE) Cable : 4.358 KM.& 2.419 KM.resp.
- Packed Substation 315kVA & 200KVA copper wound outdoor unit with 2 Isolator + 1 SFU configuration with non walkin type. : 06 Nos. &01 Nos. respectively.
- Feeder Pillar & earthing arrangements. : 56 Nos